How to install loop coil
Description:
The NBLD100 is a single channel inductive loop detector, designed for parking and vehicle access control. The function of the detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface.
Application:
- Parking boom gate control
- • Vehicle access control
- • Motorised gates and doors
- • Industrial control systems
- Toll Systems
- Traffic Control Application
- Vehicle Counting
Features:
1. Sensitivity Selection: the 16 sensitivity settings allow for finer adjustment of the detection level, it can detect the moto, also can big truck.2. Compact Size: the compact and well engineered housing Combines all of the industry requirements regarding Features and functionality and allows this detector to be Toll Systems Incorporated into any or existing traffic detection system. Traffic Analysis
3. Diagnostic Capabilities: Comprehensive diagnostics Parking Control Application Capabilities allow for accurate diagnosis of loop and Installation problems.
4. Selectable Presence Time: The output of the presence Relay can be selected to limit a detect output to a fixed time(time>30 minutes)while a vehicle remains on the loop
5. Loop Frequency Indication: 4 frequency settings providing greater flexibility in preventing crosstalk in the muti-loop applications.
6.Two separate output relays:
Presence Relay A is presence output. Can be extended for 0,2,5,8,10,15,20 or 30 seconds, programmable with external 10 way DIP switches.
Pulse Relay B, programmable with external 10 way DIP switches, provides presence, pulse on entry, pulse on exit, or failed output.
Clik the link: https://www.youtube.com/watch?v=fKmBiJAXerw
Specifications
Self-turning range: 20-2000μH Response Times: Turn-on 10-90MSTurn-off 10-90MSSensitivity: 16 way selectable Visual Indications: Power LED-RedHighest 0.010% DL/L Channel LED-GreenLowest 2.56% DL/L Reset: Reset by push button onfront of enclosureFrequency: Four step switch Relay Output: Presence Relay/Fault Relayselectable 20-80KHzPower Requirements: 110-240VAC (48 to 62Hz)12-24VADC(48 to 62Hz)Operation Temp: -40℃ to +70℃ Humidity: Up to 95% relative humidity(-111℉ to +158℉) without condensationInstall:
1. The detector should be installed in a waterproof housing as close to the loop as possible.2. The loop and feeder should be made from insulated copper wire with a minimum cross-sectional area of
1.5mm2
. The feeder should be twisted with at least 20 turns per metre. Joints in the wire are not
recommended and must be soldered and made waterproof. Faulty joints could lead to incorrect operation of
the detector. Feeders which may pick up electrical noise should use screened cable, with the screen earthed
at the detector.
3. The loop should be either square or rectangular in shape with a minimum distance of 1 metre between
opposite sides. Normally 3 turns of wire are used in the loop. Large loops with a circumference of greater than
10 metres should use 2 turns while small loops with a circumference of less than 6 metres should use 4 turns.
When two loops are used in close proximity to each other it is recommended that 3 turns are used in one and
4 turns in the other to prevent cross-talk.
4. Cross-talk is a term used to describe the interference between two adjacent loops. To avoid incorrect
operation of the detector, the loops should be at least 2 metres apart and on different frequency settings.
5. For loop installation, slots should be cut in the road using a masonry cutting tool. A 45o cut should be made
across the corners to prevent damage to the wire on the corners. The slot should be about 4mm wide and
30mm to 50mm deep. Remember to extend the slot from one of the corners to the road-side to accommodate
the feeder.
6. Best results are obtained when a single length of wire is used with no joints. This may be achieved by running
the wire from the detector to the loop, around the loop for 3 turns and then back to the detector. The feeder
portion of the wire is then twisted. Remember that twisting the feeder will shorten its length, so ensure a long
enough feeder wire is used.
7. After the loop and feeder wires have been placed in the slot, the slot is filled with epoxy compound or bitumen
filler.


Ordering Information:
LD-100 single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard)LD-102 single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard)
LD-105 single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard)
LD-105 single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard)
LD-106 single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard)
More information pls contact me: